Oval Gear Flow Meter Accuracy vs. Repeatability

Release time: 2026-11-11

The accuracy classes of commonly used oval gear flowmeters are 0.5% and 0.2%. Because the measuring chamber volume differs among nominal diameters, the corresponding flow ranges also differ. In addition, medium viscosity affects the internal leakage and pressure loss of the meter; therefore, for the same nominal diameter, the applicable flow range also varies with medium viscosity. The flow ranges corresponding to each accuracy class, nominal diameter, and medium viscosity are shown in the table below. During selection, the accuracy requirement, nominal diameter, and actual medium viscosity should be considered jointly to determine the appropriate configuration, and operation beyond the corresponding flow range should be avoided, as this may affect metering accuracy and repeatability.

   unit: m3/h

TypeDNViscosity (mPa. s)
<0.30.3~0.80.8~22~200200~ 10001000~2000
LC- 10Ⅱ10 0.08-0.250. 1-0.250.05-0.250.08-0.250.05-0.250.03-0.050.02-0.05 
LC- 1010 0.2-0.5 0.08-0.50.08-0.50.05-0.50.06-0.30.03-0.30.03-0.2
LC- 1515 0.75-1. 0.3- 1.50.3- 1.50. 15- 1.50.2- 1.00. 1- 1.00.07-0.7
LC-2020 1.5-31-30.5-30.5-30.3-30.4-2. 10.2-2. 10. 15- 1.5
LC-25254-63-62-61-61-60.6-60.8-4.20.4-4.20.3-3
LC-40409- 157.5- 155- 152.5- 152.5- 151.5- 152. 1- 10.51.0- 10.50.7-7.5
LC-505010-248-248-244.8-244.8-242.4-242.4- 16.81.6- 16.81.2- 12
LC-B40、5040 、508-206-206-204-204-202-202.8- 141.4- 141.0- 10
LC–656527-4020-4015-408-408-404-405.6-282.8-282-20
LC-808040-6030-6020-6012-6012-606-608.4-424.2-423-30
LC- 10010067- 10050- 10034- 10020- 10020- 10010- 10014-706-705-50
LC- 150150127- 19095- 19064- 19038- 19038- 19019- 19026.6- 13313.3- 1339.5-95
LC-200200227-340170-340114-34056-34056-34034-34047.6-23823.8-23817- 170
Accuracy 0.50.50.20.50.20.50.20.50.5

Oval gear flowmeters are calibrated during factory testing using the volumetric standard tank comparison method, with diesel as the medium.