Analysis of Scene Problems for Oval Gear Flowmeter
Release time: 2026-04-16
| Fault Phenomenon | Cause | Measure | Remarks |
|---|---|---|---|
| Oval gear does not rotate | 1. Debris in pipeline 2. Debris in measured liquid 3. Filter damaged Debris enters meter, gear stuck | Disassemble and clean the meter and pipeline; repair the filter | |
| Axial seal coupling leakage | Packing worn or lack of sealing oil | Tighten the gland or replace the packing; add sealing oil | |
| Pointer rotates unstably | Loose pointer or washer; moving parts not flexible | Retighten and eliminate inflexibility | |
| Small flow error too negative (excessive negative error at low flow) | Oval gear contacts measuring chamber wall due to bearing wear or chamber deformation | Replace bearings; repair deformed measuring chamber and gear; ensure flexible rotation; recalibrate after repair | |
| Large error variation | Large flow pulsation or presence of gas | Reduce pulsation or install a gas separator | For 0.2-class flowmeters, the maximum/minimum error shall not exceed ±0.17% |
| Excessive error but not exceeding ±1% | Service life exceeded or clearance changed after maintenance | Recalibrate and adjust | |
| No signal from transmitter | 1. Transmitter block improperly positioned 2. Polarity reversed | Readjust position (move forward/backward/left/right) Reconnect correctly: + to red wire, – to black wire |